Specialists in the Design, Manufacture and Application
of Power Factor & Power Quality Correction Equipment
 

Home | Products | Services | Technical & FAQs | Contact


 

General Product Lines

Low Voltage Power Capacitors

Our low voltage power capacitors are intended for the improvement of Power Factor in low voltage networks. The quality of the materials used combined with the construction methods used in the manufacturing process ensure reliability and longevity. When combined with a regular maintenance schedule this is further evidenced by some of the earliest banks we manufactured which are still in operation today some 20+ years later.

Static Power Factor Correction Banks

  • 3kVAR-200kVAR

  • 230V,480V,600V

  • single phase or three phase 230V

  • three phase capacitor banks are delta connected

  • ...custom sizes available by request

Automatic Switching Power Factor Correction Systems

  • 125kVAR-1200kVAR

  • 230,480V,600V

  • single phase or three phase 230V

  • three phase banks are delta connected

  • ...custom sizes available by request

Capacitors for Power Factor Correction

  • 3kVAR-25kVAR

  • 230V,480V,600V,690V

  • 230V available in single phase or three phase

  • three phase capacitors are delta connected

  • ...custom sizes available by request

Be sure to read the article in our Technical & FAQ section titled "Delta Vs Wye Connected Capacitors".

Detuning Reactors

Power Quality disturbances and Harmonic distortion are one of the main problems in Electrical Systems today. Harmonic Distortion and High Frequency interferences are caused by variable speed drives, soft starts, rectifiers, welding devices, UPS, discharge lamps etc… These disturbances often affect sensitive loads that are connected to the same power source. Harmonic voltage distortion also causes several other problems such as motor damage, over-heating of cables and transformers etc…

De-tuning reactors help mitigate Harmonics and High Frequency disturbances in the electrical system through their use in capacitor banks, thus reducing or eliminating harmful affects caused by harmonic distortion.

Full Range of Line/Load Reactors

Broadband Harmonic Filters

RFI/EMI Filters

Transient Voltage Surge Suppression (TVSS)

Let us show you how to make your correction pay for itself...
...all while putting money back into your hands.

Please feel free to contact us for further information.

 


Home | Products | Services | Technical & FAQs | Contact

240 Huckins St., P.O. Box 24, Goderich, Ontario, N7A 3Y5
Ph: (519) 440-0454  Fax: (519) 440-0446
email: info@cosphi.com
Copyright © Cos Phi Inc.