Effect of Voltage
Unbalance on Motor Performance
by Peter Kratochvil, President - Cos Phi Inc.
When the line voltages applied to a polyphase induction motor are
not equal, unbalanced currents in the stator windings will result. A
small percentage voltage unbalance will result in a much larger
percentage current unbalance. Consequently, the temperature rise of
the motor operating at a particular load and percentage voltage
unbalance will be greater than for the motor operating under the
same conditions with balanced voltages.
Should voltages be unbalanced, the rated horsepower of the motor
should be multiplied by the factor shown in the graph below to
reduce the possibility of damage to the motor. Operation of the
motor at above a 5 per cent voltage unbalance condition is not
recommended.
Alternating current, polyphase motors normally are designed to
operate successfully under running conditions at rated load when the
voltage unbalance at the motor terminals does not exceed 1 per cent.
Performance will not necessarily be the same as when the motor is
operating with a balanced voltage at the motor terminals.

|
Per cent Voltage Unbalance |
 |
Example:
With voltage of 460, 467 and 450, the average is
459, the maximum deviation from the average is 9, and the
Percent Unbalance = 100 x (9
4 459) = 1.96
|